Technical Characteristics:
Output |
: |
0.12 up to 370 kW |
Poles |
: |
II up to VIII |
Frame |
: |
71 up to 355M/L |
Voltage |
: |
220-240/380-415 // 460 V (up to frame 100L) |
380-415/660-690 // 460 V (frames 112 and above) |
||
Frequency |
: |
50 or 60 Hz |
Hazardous Area |
: |
Zone 1 and 2, Gas Group IIA and IIB – Gas Group IIB |
Temperature Class |
: |
T4 |
Certification Marking |
: |
Ex db IIB T4 Gb |
Enclosure |
: |
IC411 – Totally Enclose Fan Cooled (TEFC) |
Protection |
: |
IP56 |
Insulation Class |
: |
F |
Temperature Rise |
: |
B (80K) |
Ambient Temperature |
: |
-20˚ C to +40˚ C at 1000 masl |
Frame Material |
: |
Cast iron |
Bearing Cap |
: |
Internal DE and NDE bearing cap to prevent flame propagation |
Bearing Seals |
: |
Lip Seal frame 90 up to 280 (all poles) 315 up to 355 (2-pole) |
Taconite 315-355 (4 up to 8 poles) |
||
Thermal Protection |
: |
Thermistor PTC 150˚ C – 2 wires – one per phase |
Finish Colour |
: |
RAL 5010 (IE1 motor) |
RAL 5009 (IE2 motor) |
||
Standard |
: |
IEC / NEMA |
Manufacturing Site |
: |
WEG Motores (Brazil) |
Certification |
||
Certifying body: BASEEFA or INERIS |
||
Directive / Standards: ATEX & IECEx certification |